| Model
KM26
|
| K-TEK offers the standard KM26 MLG with a chamber of virtually any non-magnetic material, extruded process connections, a custom engineered float, and all accessories with 316 stainless steel construction. |
|
|
|
 |
|
|
| Model
AT200
|
| The AT200 Magnetostrictive Level Transmitter is Used as a Direct Insert for the KM26 Magnetic Level Gauge to Create a Complete Level Measuring System for a Wide Range of Total and Interface Applications. The AT200 Transmitter Features One Moving Part, a Float, that Provides Continuous Level Reading Via Common Industry Protocols Such as 4-20 mA, HART, Honeywell DE, Foundation Fieldbus, while Deriving its Source of Power from the Control Loop. The Transmitter Detects the Position of the Float within the Float Chamber by Using "Time of Flight" Technology to Calculate Distance. The Resulting, Non-Contact, Level Measurement is Highly Accurate. |
|
|
|
 |
|
|
| Model
AT100
|
| The AT100 is Based Upon the Magnetostrictive Principle. The Sensing Tube Contains a Wire, which is Pulsed at Fixed Time Intervals and the Interaction of the Current Pulse with the Magnetic Field Created by the Magnetic Float. This Causes a Torsional Stress Wave to be Induced in the Wire. This Torsion Propagates Along the Wire at a Known Velocity from the Position of the Magnetic Float and Toward Both Ends of the Wire. A Patented Piezo-Magnetic Sensing Element Placed in the Transmitter Assembly Converts the Received Mechanical Torsion into an Electrical Return Pulse. The Microprocessor-Based Electronics Measures the Elapsed Time Between the Start and Return Pulses and Converts it into a 4-20 mA Output, which is Proportional to the Level Being Measured. |
|
|
|
 |
|
|
| Model
AT100S
|
| The AT100S Magnetostrictive Transmitter is based on the Same Magnetostrictive Principle as the AT100 Model. The AT100S is a High Accuracy Sanitary Magnetostrictive Liquid Level Transmitter Suitable for CIP and SIP Applications. |
|
|
|
 |
|
|
| Model
MT2000
|
| This product is discontinued. Please contact a K-TEK sales representative for a similar part. |
|
|
|
 |
|
|
| Model
KCAP300
|
| The KCAP300™ RF Capacitance Switch is Available with KSHIELD™ Sensing Probes and Single Setponit Electronics. The KCAP300™ is Used in Bulk Solids and Liquid Applications, such as Pellets, Granules, Powders, Slurries, Flow / No Flow, Conductive Products and Interface. |
|
|
|
 |
|
|
| Model
KCAP400
|
| The KCAP400™ is a Dual Setpoint and Pump Control Capacitance Switch used in Bulk Solids and Liquid Applications. Applications include, but are not limited to, Plugged Chute Detection, Fly Ash Hopper Level, Interface, Slurries, Conductive Products and High or Low Level Alarm. |
|
|
|
 |
|
|
| Model
A02
|
| The A02 High Sensitivity RF Switch is Used in Dry Bulk and Liquid Applications and Special Applications, such as, High Temperature, Corrosive Environments, High Pressure and Special Probe Materials. |
|
|
|
 |
|
|
| Model
A75
|
| The A75 RF Level Switch is Used in Dry Bulk and Liquid Applications and Special Applications, such as, High Temperature, Corrosive Environments, High Pressure and Special Probe Materials. |
|
|
|
 |
|
|
| Model
KP
|
| The Model KP's Durable, Rugged Design in Compatible with many Bulk Solids, Pelletized and Granular Applications. The KP Rotating Paddle Switch can be Used for Level Indication of Materials with Densities of 10 lbs/ft³ and Greater. The KP is Ideal for Installations where Almost Any Dry Bulk Material is Contained in Hoppers, Silos, Bins and Tanks. |
|
|
|
 |
|
|
| Model
SLT
|
| The Model SLT is an Electro-Mechanic Level Measuring Instrument for the Continous Measuring of Level in Hoppers, Silos or Tanks. This Top Mounted System is used for Monitoring the Level in Applications, such as Powders, Small Grain Bulk Materials or Coarse Grain Bulk Materials. A Bob Weight is Mounted at the End of a Measuring Rope or Tape, which is Wrapped on a Motor Driven Rope Roller. Upon Contact with the Bulk Material, the Bob Weight Returns and is Drawn Back to its Upper Stop Position. |
|
|
|
 |
|
|
| Model
High Temperature
|
| K-TEK KM26 Magnetic Liquid Level Gauges are Fabricated to Suit Specific Process Requirements. For Extreme Temperature Environments, the KM26 MLG is factory furnished/fabricated to offer Heat Tracing and High Temperature Insulation. |
|
|
|
 |
|
|
| Model
Low Temperature
|
| K-TEK KM26 Magnetic Level Gauges are Fabricated to Suit Specific Process Requirements. For Low Temp Insulation purposes, K-TEK offers the KM26 the Low Temperature Gauge. |
|
|
|
 |
|
|
| Model
MT5000
|
| The MT5000 Series Guided Wave Radar transmitters feature a graphic display incorporated into an all digital electronics module. Using this new format K-TEK has been able to add waveform screens to the modular electronics along with easy to follow multiple choice setup menus. These menus can be changed to many different languages for easy commissioning throughout the world.
MT5000 Series Guided Wave Radar transmitters provide superior performance in tough applications. Pulses of microwave energy are directed to the product surface using a rigid rod or flexible cable type probe. This assembly has no moving parts and no loss of energy due to beam divergence.
Multiple coupler and probe types are available to accommodate applications such as knock out drums, feed water heaters, production vessels and separators. 316L stainless steel is the standard probe material however materials such as Hastelloy C-276 and Monel are available for use in acidic or caustic services.
|
|
|
|
 |
|
|
| Model
MT5200
|
| The MT5200 Measures the Level of Bulk Solids Under the Harshest of Conditions with an Industry-Leading Accuracy of ±0.20 inches (5.1 mm). K-TEK's MT5200 Overcomes the False Echoes and Complicated Set-Up Normally Associated with Conventional Non-Contact Radar Level Transmitters, while Providing Accurate Height Measurements Even Under the Harshest Conditions, Wide Variations in Operating Temperatures and Pressures and Low Dielectric Constants. The MT5200 Brings the Benefits of Radar Level Measurement to an Expanded Range of Industries that Seek an Accurate Solution to Measuring the Contents of Tanks, Silos, Hoppers, Bins, Mixing Basins, and Sumps. |
|
|
|
 |
|
|
| Model
MT5100
|
| The MT5000 Series Guided Wave Radar transmitters feature a graphic display incorporated into an all digital electronics module. Using this new format K-TEK has been able to add waveform screens to the modular electronics along with easy to follow multiple choice setup menus. These menus can be changed to many different languages for easy commissioning throughout the world.
MT5000 Series Guided Wave Radar transmitters provide superior performance in tough applications. Pulses of microwave energy are directed to the product surface using a rigid rod or flexible cable type probe. This assembly has no moving parts and no loss of energy due to beam divergence.
Multiple coupler and probe types are available to accommodate applications such as knock out drums, feed water heaters, production vessels and separators. 316L stainless steel is the standard probe material however materials such as Hastelloy C-276 and Monel are available for use in acidic or caustic services.
|
|
|
|
 |
|
|
| Model
RS85
|
| The Resonator utilizes a piezoelectric driven tuning fork that exhibits a large change in resonant frequency when immersed in any liquid. A "smart" microprocessor-based electronic unit keeps the sensor in a resonant state as it changes from dry to wet or wet to dry. The resonant frequency is continuously monitored for changes created by a wet or dry sensor and an alarm is provided via relay. The RS85 should be used when the application requires optional process connections, exotic materials of construction, coatings, finishes or adjustable time delay and density set point. |
|
|
|
 |
|
|
| Model
AT200VP
|
| The AT200 Valve Positioner is a compact, high accuracy valve position transmitter that uses K-TEK’s patented Magnetostrictive sensing technology. In the valve positioning application, the transmitter is bolted to the yoke of the actuator with two (2) mounting brackets that are supplied with the transmitter. A third bracket is secured to the stem connector. This bracket holds the magnet that provides the signal to the transmitter. |
|
|
|
 |
|
|
| Model
Flanges
|
| Flange Designations for Welded & Loose Process Connections for Transmitters & Switches |
|
|
|
 |
|
|
| Model
EC
|
| Displacer Replacer & External Chamber for Side3 of Tank Mouting of Float Level Switches and Transmitters |
|
|
|
 |
|
|
| Model
SS140XP
|
| The SureShot™140XP is an Explosion-Proof Smart Laser Transmitter that Measures Level and Distance in Challenging Environments. The SureShot™140XP Features a Compact, All-Digital Design that Provides Speed and Accuracy Regardless of Presence of Surrounding Vapor and Dust. |
|
|
|
 |
|
|
| Model
RI100
|
| The RI100 Repeat Indicator is a loop powered device designed to provide a 4-20 mA output based on process variable information provided by a primary transmitter. The RI100 gathers its data through a parallel connection using HART communications. It can be used in combination with AT100, AT200, MT2000 and MT5100 transmitters and is typically used to provide an output for a secondary level indication. |
|
|
|
 |
|
|
| Model
KSONIK™ I
|
| The KSONIK™ I is an Ultrasonic Level Transmitter capable of measuring liquid level or solid applications up to 50 ft. / 15 meters or flow rates in all types of open channel flow applications. The transmitter has a single 4-20 mADC analog output and three (3) relay outputs. A transducer is fitted to the top of a silo or tank, facing down towards the material being measured. The transmitter’s microprocessor simultaneously fires an electronic pulse to the transducer and starts a timer. The transducer converts this electronic pulse to an acoustic pulse, which is directed toward the surface of the material being measured. When the acoustic pulse contacts the surface of the material, energy is reflected back to the transducer, which converts this reflected energy back to an electronic pulse. This pulse is sent back to the microprocessor, which stops the timer and determines the “time of flight” of the signal. By combining the speed of sound through air and the “time of flight” of the pulse, the microprocessor accurately determines the level of the product. Powerful software removes false echoes from the signal and electronic filters remove ambient noise. |
|
|
|
 |
|
|
| Model
MICRO
|
| The KSONIK™ MICRO Ultrasonic Level Transmitter or Switch is designed to measure liquid (32 ft. / 10 m) and bulk solids (10 ft. / 3 m) levels. The range can be configured by the keyboard and display. The MICRO is mounted on top of the vessel or tank. The microprocessor in the MICRO fires an electronic pulse that the transducer converts into an acoustic pulse. The pulse travels to the level that is being measured and is reflected back to the transducer. The transducer then converts the energy back into an electronic signal and stops the counter in the microprocessor, which then knowing the speed of sound through the air, can accurately determine the distance. The powerful software removes false echoes and the electronic filter removes ambient noise. |
|
|
|
 |
|
|
| Model
MICRO LP
|
| The KSONIK™ MICRO LP Ultrasonic Level Transmitter is designed to measure liquid (16 ft. / 5 m) levels. The range can be configured by the keyboard and display. The MICRO LP is mounted on top of the vessel or tank. The microprocessor in the MICRO LP fires an electronic pulse that the transducer converts into an acoustic pulse. The pulse travels to the level that is being measured and is reflected back to the transducer. The transducer then converts the energy back into an electronic signal and stops the counter in the microprocessor, which then knowing the speed of sound through the air, can accurately determine the distance. The powerful software removes false echoes and the electronic filter removes ambient noise. |
|
|
|
 |
|
|
| Model
KSONIK™ III
|
| The KSONIK™ III is an Ultrasonic Level Transmitter capable of measuring two separate levels in liquid or solid applications up to 195 ft. / 60 meters, or flow rates in all types of open channel flow applications. The unit is available with two 4-20 mADC analog and five (5) relay outputs. A system can consist of up to two transducers and a single transmitter with the transducer(s) installed at the top of a silo or tank, facing down towards the material being measured. The transmitter’s microprocessor simultaneously fires an electronic pulse to the transducer and starts a timer. The transducer converts this electronic pulse to an acoustic pulse, which is directed toward the surface of the material being measured. When the acoustic pulse contacts the surface of the material, energy is reflected back to the transducer, which converts this reflected energy back to an electronic pulse. This pulse is sent back to the microprocessor, which stops the timer and determines the “time of flight” of the signal. By combining the speed of sound through air and the “time of flight” of the pulse, the microprocessor accurately determines the level of the product. Powerful software removes false echoes from the signal and electronic filters remove ambient noise. |
|
|
|
 |
|
|
| Model
K10C
|